MSA General Monitors® S5000 Gas Monitor

Part number:

Origin: Usa

دسته بندی: برند:

توان تجهیز دنا

توضیحات

4.3/5 - (3 امتیاز)
Product Specifications
COMBUSTIBLE GAS SENSOR TYPE Catalytic bead (Passive comb., XCell comb.)
Infrared (IR400)
TOXIC GAS & OXYGEN SENSOR TYPE XCell Toxic
Ammonia (NH3), Carbon Monoxide (CO), Carbon Monoxide (CO) H2-resistant, Chlorine (Cl2),
Sulfur Dioxide (SO2)
Chlorine Dioxide (ClO2)

Passive MOS, Echem, XCell Toxic
Hydrogen Sulfide (H2S)

XCell O2
Oxygen (O2)

Electrochem
Ammonia (NH3), Ethylene
Oxide (ETO), Hydrogen (H2), Hydrogen Chloride (HCl), Hydrogen Cyanide (HCN), Hydrogen Fluoride (HF), Nitric Oxide (NO), Nitrogen Dioxide (NO2)

SENSOR MEASURING RANGES Combustible 0-100% LEL (CB, IR)
Cl2 0-5, 0-10, 0-20 ppm
ClO2 0-3 ppm
CO 0-100, 0-500, 0-1000 ppm
CO, H2-resistant 0-100 ppm
ETO 0-10 ppm
H2 0-1000 ppm
HCl 0-50 ppm
HCN 0-50 ppm
HF 0-10 ppm
H2S 0-10, 0-20, 0-50, 0-100, 0-500 ppm
NH3 0-100 ppm, 0-1000 ppm
NO 0-100 ppm
NO2 0-10 ppm
O2 0-25%
SO2 0-25, 0–100 ppm
CLASSIFICATIONS DIVISIONS (US/CAN)
Class I, Div/Zone 1&2, Groups A, B, C & D T5/T4; Class II, Div/Zone 1&2, Groups E, F & G, T6; Class III
Type 4X, IP66

US ZONES
Class I, Zone 1 AEx db IIC T5 Gb
Class I, Zone 2 AEx nA nC IIC T4 Gc
Zone 21 AEx tb IIIC T85°C Db

CANADIAN ZONES/ ATEX/IECEx
Ex db IIC T5 Gb
Ex nA nC IIC T4 Gc
Ex tb IIIC T85°C Db

WARRANTY S5000 transmitter 2 years
XCell Sensors 3 years
Passive comb., MOS, IR400 2 years
Echem Sensors Varies by gas
APPROVALS CSA, FM**, ATEX, IECEx,INMETRO, ABS, DNV-GL Marine, CE Marking. Complies with C22.2 No. 152, FM 6320, ANSI/ISA/CSA/IEC/EN 60079-29-1, ANSI/ISA 12.13.01. Suitable for SIL 2.
Dimensions
HOUSING (W x H x D) 6.37″ x 5.38″ x 4.25″ (162 x 137 x 108 mm)
W/PASSIVE SENSOR 6.37″ x 7.62″x 4.25″ (162 x 193 x 108 mm)
W/DIGITAL SENSOR 6.37″ x 10.4″ x 4.25″(162 x 265 x 108 mm)
W/IR400 IR SENSOR 14.8″ x 6.0″ x 4.25″ (375 x 152 x 108 mm)
WEIGHT 8 lb. (3.6 kg), 316 SS
Environmental Specifications
OPERATING TEMPERATURE RANGE Transmitter -55°C to +75°C
CB (sintered, Zones) -40°C to +70°C
CB (screened, Div) -40°C to +75°C
MOS (sintered, Zones) -40°C to +70°C
MOS (screened, Div) -40°C to +75°C
IR (CSA) -40°C to +75°C
IR (ATEX/IECEx) -60°C to +75°C
XCell (Comb) -55°C to +60°C
XCell (Toxic/O2) -40°C to +60°C
STORAGE TEMPERATURE RANGE Housing, IR400,passive sensors -50°C to +85°C
XCell sensors -40°C to +60°C
RELATIVE HUMIDITY (NON-CONDENSING) XCell sensors, IR400, 10-95%
Passive combustible 0-95%
Passive H2S 15-95%
Mechanical Specifications
INPUT POWER 24 VDC nominal, 12 to 30 VDC
SIGNAL OUTPUT Dual 4-20 mA current source or sink, HART, Modbus, Bluetooth. Optional: w/o Bluetooth
RELAY RATINGS 5A @ 30VDC; 5A @220 VAC
(3X) SPDT – fault, warn, alarm
RELAY MODES Common, discrete, horn
NORMAL MAX POWER Without Relays
Passive comb: 5.0 W
Passive MOS: 9.8 W
IR400: 7.9 W
XCell comb: 5.0 W
XCell toxic & O2: 2.6 W
IR400 + XCell comb: 10.8 W
IR400 + XCell toxic or O2: 8.6 W
Dual XCell toxic or O2: 3.3 W
Dual XCell comb: 7.4 W
XCell comb. + XCell toxic or O2: 5.7 W

With Relays
Passive comb: 6.0 W
Passive MOS: 10.8 W
IR400: 8.9 W
XCell comb: 6.0 W
XCell toxic & O2: 3.6 W
IR400 + XCell comb: 11.8 W
IR400 + XCell toxic or O2: 9.6 W
Dual XCell toxic or O2: 4.3 W
Dual XCell comb: 8.4 W
XCell comb. + XCell toxic or O2: 6.7 W

STATUS INDICATORS 4-digit scrolling LED, icons depicting fault, warn, alarm, Bluetooth, 1 and 2 to indicate sensor reading displayed
RS-485 OUTPUT Modbus RTU, suitable for linking up to 128 units or up to 247 units with repeaters
BAUD RATE 2400, 4800, 9600, 19200, 38400, 115200
HART HART 7, Device Description (DD) and Device Type Manager (DTM) available
FAULTS MONITORED Low supply voltage, RAM checksum error, flash checksum error, EEPROM error, internal circuit error, relay, invalid sensor configuration, sensor faults, calibration faults, analog output mismatch fault
CABLE REQUIREMENTS 3-wire shielded cable for single sensor and 4-wire shielded cable for dual sensor configurations. Accommodates up to 12 AWG or 4 mm2

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

اولین کسی باشید که دیدگاهی می نویسد “MSA General Monitors® S5000 Gas Monitor”

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *

MSA General Monitors® S5000 Gas Monitor

Part number:

Origin: Usa

دسته بندی: برند:

توان تجهیز دنا

توضیحات

4.3/5 - (3 امتیاز)
Product Specifications
COMBUSTIBLE GAS SENSOR TYPE Catalytic bead (Passive comb., XCell comb.)
Infrared (IR400)
TOXIC GAS & OXYGEN SENSOR TYPE XCell Toxic
Ammonia (NH3), Carbon Monoxide (CO), Carbon Monoxide (CO) H2-resistant, Chlorine (Cl2),
Sulfur Dioxide (SO2)
Chlorine Dioxide (ClO2)

Passive MOS, Echem, XCell Toxic
Hydrogen Sulfide (H2S)

XCell O2
Oxygen (O2)

Electrochem
Ammonia (NH3), Ethylene
Oxide (ETO), Hydrogen (H2), Hydrogen Chloride (HCl), Hydrogen Cyanide (HCN), Hydrogen Fluoride (HF), Nitric Oxide (NO), Nitrogen Dioxide (NO2)

SENSOR MEASURING RANGES Combustible 0-100% LEL (CB, IR)
Cl2 0-5, 0-10, 0-20 ppm
ClO2 0-3 ppm
CO 0-100, 0-500, 0-1000 ppm
CO, H2-resistant 0-100 ppm
ETO 0-10 ppm
H2 0-1000 ppm
HCl 0-50 ppm
HCN 0-50 ppm
HF 0-10 ppm
H2S 0-10, 0-20, 0-50, 0-100, 0-500 ppm
NH3 0-100 ppm, 0-1000 ppm
NO 0-100 ppm
NO2 0-10 ppm
O2 0-25%
SO2 0-25, 0–100 ppm
CLASSIFICATIONS DIVISIONS (US/CAN)
Class I, Div/Zone 1&2, Groups A, B, C & D T5/T4; Class II, Div/Zone 1&2, Groups E, F & G, T6; Class III
Type 4X, IP66

US ZONES
Class I, Zone 1 AEx db IIC T5 Gb
Class I, Zone 2 AEx nA nC IIC T4 Gc
Zone 21 AEx tb IIIC T85°C Db

CANADIAN ZONES/ ATEX/IECEx
Ex db IIC T5 Gb
Ex nA nC IIC T4 Gc
Ex tb IIIC T85°C Db

WARRANTY S5000 transmitter 2 years
XCell Sensors 3 years
Passive comb., MOS, IR400 2 years
Echem Sensors Varies by gas
APPROVALS CSA, FM**, ATEX, IECEx,INMETRO, ABS, DNV-GL Marine, CE Marking. Complies with C22.2 No. 152, FM 6320, ANSI/ISA/CSA/IEC/EN 60079-29-1, ANSI/ISA 12.13.01. Suitable for SIL 2.
Dimensions
HOUSING (W x H x D) 6.37″ x 5.38″ x 4.25″ (162 x 137 x 108 mm)
W/PASSIVE SENSOR 6.37″ x 7.62″x 4.25″ (162 x 193 x 108 mm)
W/DIGITAL SENSOR 6.37″ x 10.4″ x 4.25″(162 x 265 x 108 mm)
W/IR400 IR SENSOR 14.8″ x 6.0″ x 4.25″ (375 x 152 x 108 mm)
WEIGHT 8 lb. (3.6 kg), 316 SS
Environmental Specifications
OPERATING TEMPERATURE RANGE Transmitter -55°C to +75°C
CB (sintered, Zones) -40°C to +70°C
CB (screened, Div) -40°C to +75°C
MOS (sintered, Zones) -40°C to +70°C
MOS (screened, Div) -40°C to +75°C
IR (CSA) -40°C to +75°C
IR (ATEX/IECEx) -60°C to +75°C
XCell (Comb) -55°C to +60°C
XCell (Toxic/O2) -40°C to +60°C
STORAGE TEMPERATURE RANGE Housing, IR400,passive sensors -50°C to +85°C
XCell sensors -40°C to +60°C
RELATIVE HUMIDITY (NON-CONDENSING) XCell sensors, IR400, 10-95%
Passive combustible 0-95%
Passive H2S 15-95%
Mechanical Specifications
INPUT POWER 24 VDC nominal, 12 to 30 VDC
SIGNAL OUTPUT Dual 4-20 mA current source or sink, HART, Modbus, Bluetooth. Optional: w/o Bluetooth
RELAY RATINGS 5A @ 30VDC; 5A @220 VAC
(3X) SPDT – fault, warn, alarm
RELAY MODES Common, discrete, horn
NORMAL MAX POWER Without Relays
Passive comb: 5.0 W
Passive MOS: 9.8 W
IR400: 7.9 W
XCell comb: 5.0 W
XCell toxic & O2: 2.6 W
IR400 + XCell comb: 10.8 W
IR400 + XCell toxic or O2: 8.6 W
Dual XCell toxic or O2: 3.3 W
Dual XCell comb: 7.4 W
XCell comb. + XCell toxic or O2: 5.7 W

With Relays
Passive comb: 6.0 W
Passive MOS: 10.8 W
IR400: 8.9 W
XCell comb: 6.0 W
XCell toxic & O2: 3.6 W
IR400 + XCell comb: 11.8 W
IR400 + XCell toxic or O2: 9.6 W
Dual XCell toxic or O2: 4.3 W
Dual XCell comb: 8.4 W
XCell comb. + XCell toxic or O2: 6.7 W

STATUS INDICATORS 4-digit scrolling LED, icons depicting fault, warn, alarm, Bluetooth, 1 and 2 to indicate sensor reading displayed
RS-485 OUTPUT Modbus RTU, suitable for linking up to 128 units or up to 247 units with repeaters
BAUD RATE 2400, 4800, 9600, 19200, 38400, 115200
HART HART 7, Device Description (DD) and Device Type Manager (DTM) available
FAULTS MONITORED Low supply voltage, RAM checksum error, flash checksum error, EEPROM error, internal circuit error, relay, invalid sensor configuration, sensor faults, calibration faults, analog output mismatch fault
CABLE REQUIREMENTS 3-wire shielded cable for single sensor and 4-wire shielded cable for dual sensor configurations. Accommodates up to 12 AWG or 4 mm2