توان تجهیز دنا، تامین کننده ابزار دقیق و تجهیزات نفت، گاز و پتروشیمی
Part number: XNX-UTSI-MNNNN
HART® over 4-20 mA output, UL/CSA/FM approved, 5 x 3/4 in. NPT entries, painted 316 stainless steel, with Modbus® output
Power Consumption
|
Configuration
|
Max Power
|
Inrush
|
|
XNX EC
|
6.2 w
|
<1A, <10ms@24VDC
|
|
XNX mV
|
6.5 w
|
<750mA <2ms@24VDC
|
|
XNX IR (Optima)
|
9.7w
|
<1A, <10ms@24VDC
|
|
XNX IR (Excel)
|
13.2w
|
<1A, <10ms@24VDC
|
Signal
| Standard | HART over 3-wire 4-20 mA (sink, source, or isolated) | |
| Optional | Modbus over RS-485 | |
| 20 mA | HART over 3-wire 4-20mA (sink, source, or isolated) compliant with NAMUR NE43 | |
| Material | Marine grade aluminum alloy or SS316. 5-coat painted finish. | ||
| Dimensions | 159 x 197 x 113.8 mm / 6.138 x 7.75 x 4.48 inches | ||
| Weight | 2.27 kg (5 lb) Aluminum 5 kg (11 lb) Stainless |
||
| Temperature* | Transmitter: -40°C to +65°C (-40°F to +149°F) | ||
| MPD**-CB1: -40°C to +65°C (-40°F to +149°F) | |||
| MPD**-I**: -20°C to +50°C (-4°F to +122°F | |||
| Relays | Type: 3 form “C” SPCO contacts for alarm and fault indication. Rating: 250 VAC, 5A/24 VDC, 5A (2 Alarm, 1 Fault) A remote reset is provided to silence alarms. (The FOUNDATION Fieldbus, relay, and Modbus options are mutually exclusive.) |
||
لطفا فرم زیر را تکمیل نمایید.