ویژگیهای عمومی Draeger X-am 8000
| Dimensions (H x W x D) | 179 x 77 x 42 mm |
| Weight | Approx. 495 g, depending on sensor configuration, without strap, without pump Approx. 550 g, depending on sensor configuration, without strap, with pump |
| Housing | Durable two-component housing |
| Display | High-contrast color display |
| Temperature | -20 °C to 50 °C |
| Pressure | 700 to 1,300 hPa (measuring function) 800 to 1,100 hPa (use in explosion-hazard areas) |
| Relative humidity | 10 to 90 % (short-term up to 95 %) r.h. |
| Alarms | Visual: 3 LED ‘red’ (gas alarms), 3 LED ‘yellow’ (device alarms) Acoustic: Multi-tone, typically 100 dB(A) at 30 cm Vibration |
| Ingress protection class | IP 68 |
| Energy supply | Lithium-ion battery, rechargeable, inductive charging |
| Operating times (diffusion) | With CatEx and 3 EC sensors: Typically 24 hours With IR and 3 EC sensors: Typically 22 hours With 3 EC sensors: Typically 120 hours With CatEx, PID and 3 EC sensors: Typically 17 hours With IR, PID and 3 EC sensors: Typically 16 hours With CatEx-, IR- and 3 EC sensors: Typically 14 hours PID only: Typically 42 hours |
| Charging times | Typically 4 hours after use during a shift of max. 10 hours |
| Start-up times | Typically <60 seconds for standard sensors |
| Data storage | 24 MB, e.g. at 10 minutes per hour of gas exposure with measuring values changing by the second on all 7 channels: approx. 400 hours |
| Pump operation | Max. hose length 45 m |
| Approvals | Explosion protection marking: ATEX / IECEx: I M1, II 1G; Ex da ia I Ma, Ex da ia IIC T4 Ga EAC: PO Ex da ia I Ma X; 0Ex da ia IIC T4 Ga X cCSAus: Class I, Zone 0, AEx da ia IIC T4 Ga; Class II, Div 1, Gr. E, F, G; C22.2 No. 152, ANSI-ISA 12.13.01:2000 ANZEx: Ex da ia I Ma, Ex da ia IIC T4 Ga Measurement performance: |