Standard measuring chamber for compressed air
Applicable for 2…16 bar
• Process connection: Plug nipple NW 7.2 (Parker series 26) or G 1/4″ female thread when using without plug nipple
• Sensor connection: G 1/2″ female thread
• Gives 2-3 liters / min of process air to the environment
• The copper capillary relaxes the compressed air and prevents the backflow of moisture from the ambient air into the measuring chamber
Cs Instrument 06993390
When using the dew point sensors, it is always recommended to use a suitable measuring chamber. In this way, the sensor can be very easily inserted and removed from any compressed air line by means of a quick coupling. The advantages of using the measuring chamber are as follows:
- Since the sensor does not have to be unscrewed, it can be easily installed and removed under pressure
- Service and calibration work is possible without interrupting production.
- The pressure dew point is measured via the measuring chamber in the same way as for inline measurement, since the same pressure prevails in the measuring chamber as in the pipeline.